User's Manual
14
Alarm command class
The ALARM_REPORT will be sent to the controller when
the batteries have been inserted properly into the Z-Wave
®
Window/Door Detector.
1. Power applied
Once the batteries has been inserted, Alarm Report
Command will be sent to Nodes in group1 to confi rm the
power status for the Z-Wave
®
Window/Door Detector.
[Command Class Alarm , Alarm Report, Alarm Level =
0x02,Alarm Type = 0x01]
2. Low battery report
When the Z-Wave
®
Window/Door Detector automatically
wakes up, it will check the battery usage. When low
battery is detected , Alarm Report Command will be sent
to Nodes in group1.
[Command Class Alarm , Alarm Report, Alarm Level =
0x02,Alarm Type = 0xFF]
3. Tamper event report
When Z-Wave
®
Window/Door Detector is pressed and
hold the tamper switch more than 10 seconds then
release, it will sent , Alarm Report Command will be sent
to Nodes in group1
[Command Class Alarm , Alarm Report, Alarm Level =
0x02,Alarm Type = 0x11]