User's Manual
13
Battery Report Command:
[Command Class Battery, Battery Report, Battery Level =
20%-100%]
Wake up command class
The Z-Wave
®
Window/Door Detector stays in sleep status
for the majority of time in order to conserve battery power.
However, it can be woken up at specifi ed intervals by
setting WAKE_UP_INTERVAL_SET command by Z-Wave
®
Controller.
After the Z-Wave
®
Window/Door Detector wakes up, it
will send Wakeup Notifi cation Command to the node ID
that requires to be report and stay awake for 5 seconds, if
no WAKE_UP_NO_MORE_INFORMATION command is
received. The Minimum wake up time is 60 seconds, the
maximum wake up time is 194 days.
Command Min MAX Default
WAKE UP 60 seconds 194 Days 1 day
Association command class
The Z-Wave
®
Window/Door Detector can be set up to 5
devices in group 2. For hardware connection details, refer to
Association chapter.