User manual
21
7 Troubleshooting:
Problem Help
The product
does not work.
• Check all cables for being connected
the right way.
• Check the function of the lamp and
switch on the mains fuse after complete
installation.
• Check the settings.
Sensivity is not
satisfying.
• Remove objects out of the detection area.
• Temperatures >40°C can cause switching
errors.
• Attend to right installation height.
• Adjust the sensivity (LUX).
Lighting time is not
satisfying.
• Adjust the lighting time (TIME).
other questions • Consult your dealer.
8Specications:
Model 95174 / 96000 95175 / 96001
Input voltage 220-240 V AC / 50 Hz
Ambient light 3-2000 Lux
Lighting time
min. 10+/-3 s
max. 12+/-2 min.
min. 10+/-3 s
max. 7+/-2 min.
Protection category IP44
Max. rated load
1200 W (incandescent lamp)
300 W (energy-saving lamp)
Minimum load 1 W
Detection distance max. 12 m (<24°C)
Detection angle 180°