Operation Manual
148
SEC
PRI
~~
+ +
--
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
CN1
-
JP
4321
D4L-PLUS
FA-Plus/C or FA-Plus
BUILDING 126
Main
To the monitors
IMPORTANT NOTES:
To wire and configure the system properly, use this instruction manual and the ones enclosed
in the internal building door panels.
The installation diagram shows the connection of a video system with two general entrance
door panels and up to 127 internal building door panels.
In case of more than two general entrance door panels, wire them as the second is connected.
In video systems, use a D4L-Plus distributor at each door panel input except on the last one.
Remove the end of line jumper of all the distributors except in the last one.
In case of audio systems only, do not use coaxial cable neither distributors. On the buildings
backbones coaxial cable must be replace by a negative wire.
Refer to the previous installation diagrams for monitors or telephones connection.
ideo installation with general entrance door panel for residential complexes.
v
Coming
from previous page
D2
OUT
CTin
D1
JP1
IN
SW1
149
INSTALLATION DIAGRAMS
1,50mm² 2,50mm²
0,25mm² 0,25mm²
RG-59 RG-59
Terminal
SECTIONS CHART
100m.
Distance
300m.
A , A , A, D
in out
V , V , V , V
in+ out+ in out
+, –, CV+, CV–
SEC
PRI
~~
+ +
--
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
CN1
-
JP
4321
BUILDING 127
FA-Plus/C or FA-Plus
Main
To the monitors
ideo installation with general entrance door panel for residential complexes.
v
For longer distances than the specified contact with your distributor.
_ _
++
D2D1
1 2 3 4
D1
D2
UNO PLUS PLUS UNO
UNO PLUS UNO PLUS
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
RD-Plus/Uno
SW1
Example of column with digital repeater
!
If any T-940 Uno or Platea Uno is connected to an internal building doorpanel, a digital
repeater RD-Plus/Uno must be used, installed as shown in the diagram.
!