Make a call to make sure that the telephone has been properly
programmed. Repeat these steps to program the rest of telephones.
Once the programming has been finished exit from the programming
menu by pressing key. If you don't, the door panel will automatically
exit after 90 seconds with no operation.
Only for T-940 Uno and T-740 Uno telephones:
O.K.
01
O.K.
01
TELEPHONES PROGRAMMING
rogramming the telephones.
P
To program the telephone as master, put down
the handset.
To program it as slave, press the door release
push button and then put down the handset.
Each apartment must have one master unit only; in case of parallel units configure them
as slaves, both monitors or telephones.
Enter the code that will be used to call to
this telephone and press the key.
At this moment the panel and the telephone
handset will reproduce a sound.
To show that the system is ready for programming, the panel
will reproduce a sound and the LCD will display the
message program mode. At this moment, the door
release push button can be released. Audio communication
with the door panel is enabled.
Press the door release pushbutton and with this button
pressed, pick up the handset.
For all the telephones:
139
MRBO T
R-3
TF-104
SEC
~~
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
CN1
-
INSTALLATION DIAGRAMS
onnexion of an a.c. lock release.
C
As it is described on page 125, the lock releases to be connected to the door panel
must be d.c. type. If an a.c. lock release has been installed before, use a R-3
relay unit and a TF-104 transformer, and connect them to the lock release
as it is shown on the enclosed diagram.
ink of several power supplies units.
L
If the quantity of monitors or telephones to be connected is bigger than the supported
from one power supply (see page 125), use additional power supplies to match the
required quantity. The first power supply should be connected to the door panel and
to the first group of monitors or telephones; connect the next groups to the positive
terminal of its corresponding power supply.
To wire several power supplies link their ground terminals;
NEVER link positive terminals of different power supplies.
To the door panel and to
the first group of monitors
or telephones.
To the second group of
monitors or telephones.
1st FA-Plus 2nd FA-Plus/C or FA-Plus
SEC
PRI
~~
Main
+ +
--
SEC
PRI
~~
Main
+ +
--
Door panel
1
4
7
2
5
8
3
6 0
9
C