Product Manual
20
VIII Common Failures and Trouble Shooting
1. Failures: Motor don’t run
Cause (1): The battery capacity is not enough, the battery is in automatic protection when the
power light becomes red.
solution:Check if the battery is adequate.
Cause :(2) The range button not settled.
Solution: adjust it to zero
Cause: (3) Overload operation
Solution: Stop working and put the machine at a ventilated place for 30minutes.
2. Failures:Machine runs but without spraying droplets
Cause: (1) The solution is not enough or no solution.
Solutions:Check and fill more solution into the tank.
Cause: (2) Solution tank cap is not well fastened.
Solution: Fasten the solution cap.
Cause: (3) Spray nozzle blockage.
Solution: Clean the nozzle.