SDS

SAFETY DATA SHEET
GOJO® Luxury Foam Antibacterial Handwash
Version 1.2
SDS Number: 400000000188
Revision Date: 10/17/2019
3 / 17
and use the recommended protective clothing
SECTION 5. FIREFIGHTING MEASURES
Suitable extinguishing media
:
Use water spray, alcohol-resistant foam, dry chemical or
carbon dioxide.
Unsuitable extinguishing
media
:
High volume water jet
Specific hazards during
firefighting
:
Do not use a solid water stream as it may scatter and spread
fire.
Cool closed containers exposed to fire with water spray.
Flash back possible over considerable distance.
May form explosive mixtures in air.
Exposure to decomposition products may be a hazard to
health.
Carbon oxides
Sulphur oxides
Nitrogen oxides (NOx)
Hazardous combustion
products
:
Carbon oxides
Sulphur oxides
Nitrogen oxides (NOx)
Specific extinguishing
methods
:
Use extinguishing measures that are appropriate to local
circumstances and the surrounding environment.
Use water spray to cool unopened containers.
Further information
:
Collect contaminated fire extinguishing water separately. This
must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must
be disposed of in accordance with local regulations.
Special protective equipment
for firefighters
:
In the event of fire, wear self-contained breathing apparatus.
Use personal protective equipment.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions,
protective equipment and
emergency procedures
:
Use personal protective equipment.
Ensure adequate ventilation.
Remove all sources of ignition.
Evacuate personnel to safe areas.
Keep people away from and upwind of spill/leak.
Material can create slippery conditions.
Environmental precautions
:
Discharge into the environment must be avoided.
Prevent further leakage or spillage if safe to do so.
Retain and dispose of contaminated wash water.
Local authorities should be advised if significant spillages
cannot be contained.
Methods and materials for
containment and cleaning up
:
Non-sparking tools should be used.
Soak up with inert absorbent material.
Suppress (knock down) gases/vapours/mists with a water
spray jet.
Keep in suitable, closed containers for disposal.
Clean contaminated floors and objects thoroughly while
observing environmental regulations.