User's Manual

Activity Counter Installation and Service
User Guide
August 22, 2013 8
Set-up and Calibration
Once mounted, the Activity Counter can be powered-up and tested for functionality. Refer to the
diagram below for making adjustments.
Slide the ON/OFF switch to apply power to the Activity Counter. The red and green LED’s will flash
alternately for a few seconds. Once both LED’s are off, the Activity Counter is ready to test. To test the
Activity Counter, begin by clearing the area of all persons. Next have someone walk completely past the
Activity Counter while observing the LED’s. After a brief pause, have the person turn around and walk in
the opposite direction, until completely past the Activity Counter, while continuing to monitor the LED’s.
After entering the area in which the Activity Counter is installed, the green LED should light briefly, after
exiting the area in which the Activity Counter is installed, the red LED should light briefly.
There is a short delay period after the Activity Counter registers an event during which subsequent
events are ignored. This period can be useful to prevent the Activity Counter from registering multiple
events in rapid succession that might actually be caused by someone hesitating under the doorway, etc.
This “dwell time” can be set to one of four different levels. This dwell time is active during the period in
which either the red or green LED is lit after an event is detected. Additionally, the Activity Counter can
be set to either high or low sensor sensitivity. The dwell time and sensor sensitivity are configurable
Antenna
Dwell Time / Sensitivity Adjustment
On/Off Switch