Activity Counter Installation and Service
User Guide
August 22, 2013 6
Adhesive mount
An adhesive pad is included for situations where screws are not desired or practical.
Peel the release liner off one side of the adhesive pad and apply it to the mounting plate of
the Activity Counter
Position the mounting plate with the arrow pointing toward the door or entry.
Peel the remaining release liner off the adhesive pad and firmly press the pad and mounting
plate against the surface of the ceiling or wall
Once the mounting plate has been secured, position the Activity Counter over the tabs on
the plate and twist clockwise to finish the installation. Note that the mounting plate is
keyed so that the Activity Counter will only fit in one orientation.
Optional Universal Mount
A mounting bracket can be used to mount in areas where a direct mount is not optimal. The optional
Universal Mount allows for the Activity Counter to be angled and positioned such that the flow of traffic
will pass though the counter’s detection beam.
Attach the mounting plate of the Activity Counter to one of the base plates of the Universal
Mount using the four (4) self-threading screws provided.
Screw mount
It is preferred that the Universal Mount be directly fastened to the ceiling or wall with hardware.
There are four (4) holes for mounting on the base of the Universal Mount.
Position the remaining base plate on the ceiling or wall.
Use the base plate as a template to mark the four hole locations. At a minimum; use the upper
two hole location for mounting
If mounting directly to a wood stud; Pre drill using a 1/8” (3mm) bit and secure to the ceiling or
wall with #10 screws (not included).
If mounting to Metal Stud, Drywall, Concrete, or brick drill holes for use #10 wall anchors and
secure with wall anchors and #10 screws.
Attach Mounting Plate
Mount Base Plate to Wall