User Manual

DP300 II
300Ws
58
DP400 II
400Ws
65
DP600 II
600Ws
80
DP800 II
800Ws
88
DP1000 II
1000Ws
92
0.3-1.2s
0.4-2s
0.3-1.5s
Tube Replacement
Shut down the power and remove the power cord before replacing the flash tube
and wear insulated gloves. Then, loosen the iron wire on the tube, keep a balanced
hold on the two feet of the flash tube and pull out the old tube gently. Take down the
feet casing from the old tube and put it on the new one. Hold two feet of the new
tube, and target directly towards the two copper outlets, then push them slightly in.
Twine the iron wire on the stainless steel sheet to fix the flash tube.
The flash unit is built in with a Wireless Control Port so that you can
wirelessly adjust the power level of the flash and the flash triggering.
To control the flash wirelessly, you need a FT-16 remote control set (on-
camera and on-flash). Insert its receive end into the Wireless Control
Port on the flash and insert the transmit end into the
camera hot shoe. Settings made on the hotshoe-
mounted transmit and receive ends will be wirelessly
communicated to the flash. Then you can press the
camera shutter release button to trigger the flash. You
can also hold the transmit end at hand to control your
off-camera flash.
For full instructions on the use of FT series remote control, see its
user manual.
TECHNICAL DATA
Recycle Time
Dimension
Net Weight
MAINTENANCE
Flash diameter12.5CM, height of flash with handle 21.5CM,
length of flash with lamp cover 42CM
Shut down the device immediately when it works abnormally and find out the reason.
Avoid sudden impacts and the lamp should be dedusted regularly.
It is normal for the lamp to be warm when in use. Avoid continuous flashes if unnecessary.
Maintenance of the flash must be performed by our authorized maintenance department
which can provide original accessories. The flash-tube and the modeling lamp are
user-replaceable. Replacement tubes and lamps can be obtained from the manufacturer.
This product, except consumables e.g. flash tube and modeling lamp, is supported with
a one-year warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired by professionals.
Disconnect the power when cleaning the flash or when changing the flashtube /
modeling lamp.
Changes made to the specifications or designs may not be reflected in this manual.
5600±200K
AC110V-120V~60Hz or AC220V-240V~50Hz
OFF, 6.0~10.0(1/16~1/1)
150W
Sync cord, Test button, Slave triggering, Wireless control port
1/2000~1/800s
5V
5V/200mA (only for Godox receiver)
Model
Max Power (WS)
Guide Number(m ISO 100)
Color Temperature
Operating Voltage
Power Output Control
Modeling Lamp (W)
Triggering Method
Flash Duration
Parameters Output from
the Sync Cord Jack
Parameters Output from
the USB Port
Fuse
Approx. 2.5kg 2.59kg 3.02kg 3.2kg 3.3kg
- 18 -- 17 -
8A
5A