Installation & Operation Manual

TST-770 WSD Full Line Manual-RevA
© 2021 Truck System Technologies and Pressure Systems International Inc. All Rights Reserved Worldwide.
support@TSTtruck.com (770) 889-9102 M-F 9-8pm, Sat 9-2pm EST
Page 38
SENSOR SPECIFICATIONS
Operating Temperature Range -40°F - 17F / -40°C - 80°C
(Internal) -40°F - 230°F / -40°C - 110°C
Storage Temperature Range -40°F - 185°F / -40°C - 85°C
(Internal) -40°F - 248°F / -40°C - 120°C
Pressure Range 1-218 PSI / 1-15 BAR
Pressure Accuracy Range (w/digital gauge)
±1.5 PSI / ±0.1 BAR
Temperature Accuracy Range ±5.4°F / ±3°C
Transmission Power <10 dBm
Transmission Frequency 433.92 MHz
Approximate Battery Life 1-1.5 years (up to 4 years for Internal)
Physical Sensor Size - Flow-Thru (CR1632) 2.2'' (L) x 1" (W) x 0.9" (H)
52 (L) x 26 (W) x 23.5 (H) mm
Physical Sensor Size - Flow-Thru (CR2032) 1.7'' (L) x 1" (W) x 0.94" (H)
42.6 (L) x 26.8 (W) x 24 (H) mm
Physical Sensor Size - Cap 0.96'' (D) x 0.91" (H)
24.4 (D) x 23.1 (H) mm
Physical Sensor Size -
Internal Screw-mounted
2.64” (L) x 1.26” (W) x 0.70” (H)
67 (L) x 32 (W) x 18 (H) mm
Physical Sensor Size -
Internal Belt-mounted
2.6” (L) x 1.26” (W) x 0.79” (H)
66 (L) x 32 (W) x 20 (H) mm
Physical Sensor Size - Hybrid Cap 1.16” (D) x 1.02 “ (H)
29.5 (D) x 26 (H) mm
Sensor Weight - Flow-Thru (CR1632) 0.77 oz. / 22 grams
Sensor Weight - Flow-Thru (CR2032) 0.99 oz. / 28 grams
Sensor Weight - Cap 0.59 oz. / 16.8 grams
Sensor Weight - Internal Screw-mounted 1.38 oz. / 39 grams
Sensor Weight - Internal Slide-on 1.46 oz. / 41.5 grams
Sensor Weight - Hybrid Cap 0.88 oz. / 25 grams
DISPLAY SPECIFICATIONS
Temperature Operating Range -4°F - 176°F / -2C - 80°C
Storage Temperature Range -22°F - 185°F / -30°C - 85°C
Display Input Voltage 5 to 24V DC
Frequency 433.92 MHz
Size 5.28”(L) x 4.59”(W) x 0.83”(D)
134(L) x 116.5(W) x 21(D)mm
Display Weight 8.35 oz. / 236.5 grams
Back To TABLE OF CONTENTS