Section 7- Handling and Storage
Handling
The battery should not be opened, destroyed or incinerate, since they may
leak or rupture and release to the environment the ingredients that they
contain in the hermetically sealed container.
Do not short circuit terminals, or over charge the battery, forced
over-discharge, throw to fire.
Do not crush or puncture the battery, or immerse in liquids.
Storage
Avoid mechanical or electrical abuse. Storage preferably in cool, dry and
ventilated area, which is subject to little temperature change. Storage at high
temperatures should be avoided.
Do not place the battery near heating equipment, nor expose to direct
sunlight for long periods.
Other Precautions
The battery may explode or cause burns, if disassembled, crushed or
exposed to fire or high temperatures. Do not short or install with incorrect
polarity.
Section 8- Exposure Controls/Personal Protection
Engineering Controls
Use local exhaust ventilation or other engineering controls to control sources
of dust, mist, fumes and vapor.
Keep away from heat and open flame. Store in a cool, dry place.
Personal Protective Equipment
Respiratory Protection: Not necessary under normal conditions.
Skin and body Protection: Not necessary under normal conditions, Wear
suitable protective clothing and gloves if handling an open or leaking battery.
Hand protection: Wear suitable gloves if handling an open or leaking battery.
Eye Protection: Not necessary under normal conditions, Wear safety glasses
if handling an open or leaking battery.
Other Protective Equipment
Have a safety shower and eye wash fountain readily available in the
immediate work area.
Hygiene Measures
Do not eat, drink, or smoke in work area. Maintain good housekeeping.
Section 9- Physical and Chemical Properties
Form
Solid
Color
Purple
Odour
No available
pH
No available
Melting point/freezing point
No available
Boiling Point and Boiling range
No available
Flash Point
No available