Solar Controller User Manual (GP-PWM-30-UL)

GP-PWM-30-UL
_______________________________________________________________________
21
© 2019 Go Power!
8.7 Errors
Over Voltage
If the GP-PWM-30-UL
experiences a battery over
voltage (>15.5 VDC) on
battery bank 1, the controller
will stop operating, and the
display will begin to flash with
all icons. The controller will
resume operating when the
voltage drops to a normal level
<15.5 VDC.
Icons Displayed: All symbols
The controller does not display over voltage on battery 2.
Low Voltage
Low battery 1: If the SOC of
battery bank 1 reaches 0%,
the battery SOC symbol will
show the text “LOW” beneath
it. The controller will continue
operating in this condition and
will only stop operating if the
voltage of Battery 1 drops
below 9.0 VDC.
Low battery 2: If there are
two battery banks connected
and the SOC of battery bank 2
reaches 0%, the battery SOC
symbol will show the text
“LOW” beneath it. The
controller will continue
operating in this condition and
will only stop operating if the
voltage of Battery 1 drops
below 9.0 VDC (this is
because the GP-PWM-30-UL
is powered by Battery 1).
Icons Displayed: Battery SOC Symbol, LOW, Symbol 1 or 2