Solar Controller User Manual (GP-PWM-30-UL)

GP-PWM-30-UL
_______________________________________________________________________
11
© 2019 Go Power!
3. Select wire type and gauge. If this GP-PWM-30-UL was purchased as
part of a Go Power! Solar Power Kit, appropriate wire type, gauge and
length is provided. Please continue to Section 8, “Operating
Instructions.” If the GP-PWM-30-UL was purchased separately, follow
the instructions included here.
Wire type is recommended to be a stranded copper UV resistant wire. Wire
fatigue and the likelihood of a loose connection are greatly reduced in stranded
wire compared to solid wire. Wire gauge should be able to sustain rated current
as well as minimize voltage drop.
Wire Strip Gauge
You will find a strip gauge diagram
on the back of the GP-PWM-30-UL,
which helps you to strip your wires to
the correct length. Insert wire into the
concave slot of the strip gauge until it
meets the back of the Strip Gauge
slot. Mark the length of wire from the
back of the Strip Gauge slot to the
edge of the controller with a pen or
your finger and strip all wires to be connected to the controller to this length.
Suggested Minimum Wire Gauge
(Cable length 25 ft. max. from solar array to battery bank)
Wire Type Wire size min (AWG) Wire size Max (AWG)
Copper Only, 90°C AWG 10 AWG 4
IMPORTANT: Identify the polarity (positive and negative) on the cable used for
the battery and solar module. Use colored wires or mark the wire ends with tags.
Although the GP-PWM-30-UL is protected, a reverse polarity contact may
damage the unit.
Wiring the GP-PWM-30-UL. Wire the GP-PWM-30-UL according to the wiring
schematic in Section 7. Run wires from the solar array and the batteries to the
location of the GP-PWM-30-UL. Keep the solar array covered with an opaque
material until all wiring is completed.
IMPORTANT: All wiring must be in accordance to National Electrical Code,
ANSI/NFPA 70.
4. Connect the battery wiring to the controller first and then connect the
battery wiring to the battery.
5. Torque all terminal screws per the following: