User Manual
gpelectric.com | [page 23]
6. OPERATING
1. The installation is complete. Remove the opaque material from the solar panels.
2. Switch the Circuit Breaker and Solar Disconnect(s) to the on position.
3. Follow the GP-MPPT-PRO-60 User Manual for setup and operating steps.
7. SPECIFICATIONS
GP-PV-190M Solar Panel Specs
Rated power (Pm) 190W
Maximum power voltage (Vmp) 20.4V
Maximum power current (Imp) 9.45A
Open circuit voltage (Voc) 24.1V
Short circuit current (Isc) 9.98A
GP-MPPT-PRO-60 Specs (Detailed specs available in the manual)
Maximum Solar Array Current 40A (amperage is reduced above 50˚C)
Maximum Solar Array Power 600/1200W
Maximum Solar Voltage 150VDC
Solar Disconnect
Maximum Voltage 600VDC
Maximum Current 25A
Circuit Breaker
Rating (amperage, maximum voltage) 80A, 48VDC
Class Type III - switchable/manual reset - trip free