User Manual

[page 32] | gpelectric.com
4.5 DIP SWITCH (S1~S8)
Switch# Switch Assignment
1 AC output voltage setting
2 AC output voltage setting
3 AC output frequency setting
4 Energy-saving level
5 Energy-saving level
6 Energy-saving level
7 To set-up DIP Switch S4~S6 for power saving
8 To set-up function parameters adjustment via DIP switch
S1 S2 S3 S4 S5 S6 S7 S8 Scenario
0
0 X X X X X X AC output voltage : 100VAC/200VAC
1
0 X X X X X X AC output voltage : 110VAC/220VAC
0
1 X X X X X X AC output voltage : 115VAC/230VAC
1
1 X X X X X X AC output voltage : 120VAC/240VAC
X
X 0 X X X X X AC output frequency : 50Hz
X
X 1 X X X X X AC output frequency : 60Hz
X
X X X X X 0 X Power saving mode setting (S4~S6)
X
X X X X X X 0 Function parameters are the default value
X
X X X X X X 1 Adjust function parameters via DIP switch