3.4.3 AC OUTPUT AND TERMINALS OF THE GP-SW1500TS
Model
Voltage
(VAC)
Total Current
(A)
*UL458
120 20
NOTE
In case the load current over the outlet rated current, please use the hard wire terminal
next to the outlets.
WARNING!
When using full power, it is recommended to use the wiring terminal.
3.4.4 GFCI (GROUND FAULT CIRCUIT INTERRUPTION)
Compliance with UL standards requires that Go Power! test and recommend specic GFCIs for
use on the AC output of the GP-SW1500TS. GFCIs shall be installed in the AC output wiring
system to protect all branch circuits. A GFCI is a device that de–energizes a circuit when a
current exceeds a specied value that is less than that required to open the circuit breaker.
GFCIs are intended to protect people from electric shocks and are usually required in wet or
damp locations. The table below lists GFCIs that have been tested and will function properly
when connected to the AC output of the GP-SW1500TS.
Manufacturer Model Number
Cooper Wiring Devices Type SGF20. Rated 125V, 20A
Leviton Mfg Co Inc Type GFNT2. Rated 125V, 20A
Hubbell Inc Wiring Device Dev Type GFRST20. Rated 125V, 20A
Pass & Seymour Inc Type 2097. Rated 125V, 20A