Electrical Specication Item GP-IC-2000
Inverter
Mode
Input
Nominal Voltage 12 VDC
Absolute Max. DC Input 25 VDC
HBCO / HBCI 17 VDC ±0.3V
LBCO / LBCI 9.0 VDC ±0.3V
Input Voltage Range 9 - 17 VDC ±0.3V
Input Over-Voltage Protection 16.5 - 17 VDC
Input Under-Voltage Protection 9 - 10.5 VDC
Max DC Input Current 267 ADC
No Load Power Consumption 25W
Stand-By Power Consumption <5W
Output
Continuous Output Power 2000W
Surge Power
5 sec 3400W
30 sec 3200W
5 min 2900W
30 min 2300W
Frequency 60 Hz
Output Voltage
120 VAC +/-5%(
≦ Continuous Power)
MaxEfciency >90%
Short Circuit Protection Yes
Output Waveform Pure Sine Wave (THD <5%)
Charger
Mode
Charger
Battery Temperature Protection Yes
AC Input Voltage Range 80 - 140 VAC±5%
AC Input Frequency Range 47 - 63 Hz
AC Input Current Range 5 - 50A
AC Nominal Current 15A
ChargerPeakEfciency 85%
Power Factor Correction >0.97 (50% Load)
Charging Current Range 0 - 100A
Battery Temperature Compensation 25 mV per °C
Four State Charging Bulk, Absorb, Float, Equalize
Equalization
Max Output Voltage 16 VDC
Max Output Current 10A
Bypass Relay RelaySpecication 50 AAC (per leg)
Operating Temperature
Range
Full Load -20°C to 40°C
Power De - Rating 60W per °C from 41°C - 60°C
Storage -30°C to 70°C
Over temperature protection Transformer, MOSFETs, Battery
Operating Humidity Range 0-95% Non-condensing
Ground Relay Default is Open (AC Pass Through Mode)
Mechanical
Specication
Size (WxHxD)
12.6” x 6.9” x 13.7”
(321mm x 175mm x 349mm)
Net Weight 17.6 Kg (38.71 lbs)
Safety and EMC
Safety Standards UL 458, UL 1741, CSA 22.2 No.107.1-01
EMC Standards FCC Class B
5. SPECIFICATIONS