OPERATION
4.7 BATTERY TEMPERATURE SENSOR (BTS) OPERATION
The GP-IC-2000 is delivered with a battery temperature sensor. By installing this sensor the charge voltages are automatically
adaptedfordeviatingtemperature.WithaBTSinstalled,ifthetemperaturearoundtheBTSisbelow20°Ctheabsorbandoatcharge
voltageincreases.IfthetemperaturearoundtheBTSisabove20°C,theabsorbandoatchargevoltagedecreases.Thegraph
below details how much the charge voltage changes (increases or decreases) depending on the temperature reading of the BTS.
4.8 FACTORY DEFAULT VALUES
The GP-IC-2000 uses default values for the following adjustable settings;
Adjustable Settings Default Values
Shore Input 30 Amps (AC)
Low Battery Cut Out 10.5 VDC
VAC Dropout 85 VAC
Max Charge Time 12 Hours
Battery Type AGM 1
Charge Rate 80%
ABS Charge Time 2 Hours
These settings are only adjustable with the GP-IC-2000 remote, which can be purchased separately from Go Power!. For
detailed information on these settings please refer to the remote control manual. The remote also displays the real time Inverter
/Chargersoperatingstatusandallowstheusertoruntheequalizechargingproleonthebatterybank.