GP-FLEX-200/100/100E - Product Manual

gpelectric.com
7
GP-FLEX-100
GP-FLEX-200
GP-FLEX-100E
8.0 Diagrams
Diagram 1:
MC4 Power Cabels For Solar Flex
TM
Kits
The MC4 power cable is usually the nal connection between the solar array and
the solar controller. If it has not already been done, cut the MC power cable into
two pieces so that there is a positive conductor cable and negative conductor
cable.
1. Cover the solar module(s) with an opaque material. Attach the appropriate
MC4 power cable conductor to the positive and negative connectors of the
MC4 junction box. If you have more than one module, refer to the specic
diagram for wiring a parallel MC4 connection.
2. Run the positive and negative MC4 cable conductors from the solar array to
the solar controller. Attach a positive polarity label to the end of the positive
conductor. If the positive conductor needs to be shortened and the polarity
label is removed, remember to re-label it as both positive and negative
conductors look exactly the same. Leave a few feet of cable at the solar
controller in case of future adjustment.
Note:
Solar module junction box and MC4 cables many not be exactly as shown.
Negative MC4
Cable Conductor
Positive MC4
Cable Conductor
Cut 50’ wire in half to
make two 25’ cables
Female (negative) MC4
Junction Box Connection
JUNCTION BOX
Male (positive) MC4
Junction Box Connection
Diagram 2:
Wiring Parallel (2) Modules with MC4 Parallel Branch Connectors (GP-FLEX-200, GP-FLEX-100E)
Note:
Solar module junction box and MC4 cables many not be exactly as shown.
Female (negative) MC4
Parallel Branch Connector
Male (positive) MC4
Parallel Branch Connector
MC4 Extension Cable to Solar
Controller or Combiner Box
JUNCTION BOX