Flex 30 Solar Panel Specs
Rated power (Pm) 30W
Maximum power voltage (Vmp) 17.5V
Maximum power current (Imp) 1.70A
Open circuit voltage (Voc) 21.0V
Short circuit current (Isc) 1.88A
Flex 50 Solar Panel Specs
Rated power (Pm) 50W
Maximum power voltage (Vmp) 17.5V
Maximum power current (Imp) 2.88A
Open circuit voltage (Voc) 19.0V
Short circuit current (Isc) 3.04A
Flex 100 Solar Panel Specs
Rated power (Pm) 100W
Maximum power voltage (Vmp) 17.5V
Maximum power current (Imp) 5.71A
Open circuit voltage (Voc) 21.0V
Short circuit current (Isc) 6.28A
GP-PWM-10 Specs (Detailed specs available in the manual)
Maximum Output Current 10A at 104˚F (40˚C)
Maximum Solar Panel Wattage at STC 160W at 12V
Maximum PV Open Circuit Voltage (Voc) 28VDC absolute maximum at coldest conditions
GP-PWM-30 Specs (Detailed specs available in the manual)
Maximum Output Current 30A at 104˚F (40˚C)
Maximum Solar Panel Wattage at STC 488W at 12V
Maximum PV Open Circuit Voltage (Voc) 28VDC absolute maximum at coldest conditions
10A ATO Blade Fuse
Max DC Voltage 32VDC
Trip Amps 13.5A
Polarized No
30A ATO Blade Fuse
Max DC Voltage 32VDC
Trip Amps 40.5A
Polarized No