Note: If the WLS is connected To a high current DC power line, a 4A
slow blow fuse, suitable for up to 100VDC should be placed on
the negative (-) wire.
Noter: Si le WLS est connecte a une puissante alimentation CC, un
fusible 4A Slow Blow pouvant soutenir jusqu’au 100VDC doit
être place sur le câble négative (-).
The WLS unit is connected to the WLS power supply via the lightning protector. It is
highly recommended that you place the WLS power supply in an indoor location.
Alternatively, if the WLS unit is not connected to the power supply, but to a fixed DC
line (for example, in a cellular base station) that is effectively not limited in current,
a circuit breaker must be placed between the DC source and the lightning protector.
The circuit breaker is rated at 4 ampere, and is reliable for up to 100 VDC.
The WLS unit is also connected, again through the lightning protector, to the WNC
unit, which offers connectivity to the Internet as well as global and local spectrum
management.