The WLAN Sector Base Station can be mounted on either a pole or a wall to provide
maximum exposure and is designed to operate either indoors or outdoors without
any degradation of service.
WLS Safety Information
RF Exposure
This outdoor access point product has been found to be compliant to the
requirements set forth in CFR 47 section 1.1307 addressing RF Exposure from radio
frequency devices as defined in OET Bulletin 65. The outdoor access point should be
positioned more than 8 inches (20 cm) from your body or nearby person.
WLS Lightning Protector
When the WLS unit is installed in an outdoor location, all indoor components
(Ethernet, power supply) should be connected through a lightning protector.
WLS Power Supply
MBW-WLS-3100
Router \ Switch
Lightning Protector
WLS Power Supply
MBW-WLS-3100
Router \ Switch
Lightning Protector
The purpose of the lightning protection is to protect people and equipment located
indoors from lightning that might strike the WLS or its outdoor cables. Therefore,
the lightning protector (3001) device should be installed indoors, as close as possible
to the point where the cables enter the building. The lightning protector can also be
installed outdoor, as long as the cables that go from it indoors are well protected
from lightning between the box and the building entrance.