Grounding Cable
Connect a grounding wire to the grounding screw at the bottom of the WLP
unit. A 10 AWG grounding cable is required to ground the WLP unit.
Figure 9: Grounding Connection
To ground the WLP unit:
1. Crimp the solderless ring terminal [A] contained in the WLP
Connectors Kit to the grounding cable.
2. Attach the solderless ring terminal [A] to the bottom of the WLP unit
using the grounding screw.
3. Connect the other end of the grounding cable to a proper ground.
Note: Connect the 10 AWG grounding cable before connecting any other
cables. When removing the WLP, the grounding cable should be the
last cable removed.
Noter: Connecter la prise de terre 10 AWG avant de connecter tout autre
câble. Pendant la désinstallation du WLP, la prise de terre doit être le
dernier câble retiré.
Ethernet Connection
Ethernet connection is used for wired backhaul connection or an interface
to a third party wireless BH solution. Use outdoor rated CAT5 shielded
cables or better. The outer diameter of the Ethernet cable should be 4.8 –
7 mm. When using CAT5 shielded cables the cable can be up to 100
meters.