User's Manual
Table Of Contents
- Table of Contents
- Introduction
- GO Wireless LAN Pico Base Station (WLP)
- Installation
- Configuring the WLP
- Connect and Access the WLP
- Configuring the Management Connectivity
- Configuring the Device Prompt
- Configuring the Radio Settings
- Configuring Multiple SSIDs
- Deleting an SSID
- Configuring the Mesh Network
- Configuring WDS CPE connection
- Configuring Authentication Types
- Configuring the Radius Client in the WLP
- Configuring Privacy Methods
- Saving the Configuration
- WLP Configuration Example
- Upgrading the WLP Software
- Appendix A: List of Acronyms
- Appendix B: Wiring Specifications
- Page 14 of 38 -
All contents are Copyright © 2006 GO Networks, Inc. All rights reserved.
Terminals
B1 and B2
5 GHz
Antennas
Figure 8: 5 GHz Band Antennas Installation
Cable Connections
When the WLP is properly aligned, the connecters are located at the
bottom of the unit.
Cable requirements are often unique to the location and deployment
topology of each installation. As a result of this limitation, the Ethernet and
grounding cables are not included in the installation kit.
The following cables are required to install the WLP unit and should be
connected in the following order:
• Grounding Cable – Provides the necessary electrical safety
functions.
• Ethernet Cable – Required only for WLP units connected to a wired
network.
• Power Cable – Supplies AC power to the WLP unit. The supplied AC
power cable is designed to connect directly to a photocell power
adapter.
• RS-232 Console Cable – Provides a connection from the WLP unit
to a console (laptop computer) for configuration. This is only
required when the WLP unit is not pre-configured. This cable is not
provided with the WLP unit. It is recommended that the WLP is pre-
configured prior to installation.