To ground the MBW 510 unit:
1. Crimp the solderless ring terminal [A] contained in the MBW 510
Connectors Kit to the grounding cable.
2. Attach the solderless ring terminal [A] to the bottom of the MBW
510 unit using the grounding screw.
3. Connect the other end of the grounding cable to a proper ground.
Note: Connect the 10 AWG grounding cable before connecting any other
cables. When removing the MBW 510, the grounding cable should be
the last cable removed.
Noter: Connecter la prise de terre 10 AWG avant de connecter tout autre
câble. Pendant la désinstallation du MBW 510, la prise de terre doit
être le dernier câble retiré.
Ethernet Connection
Ethernet connection is used for wired backhaul connection or an interface
to a third party wireless backhaul solution. Use outdoor rated CAT5
shielded cables or better. The outer diameter of the Ethernet cable should
be 4.8 – 7 mm. When using CAT5 shielded cables the cable can be up to
100 meters.
Following is a diagram explaining how the Ethernet cable should be
assembled prior to connecting it to the MBW 510 unit:
Figure 9: Ethernet Cable Connector