Deployments of gateway devices connected by wire to an indoor
switch/router would include installation of a lightning protector. A lightning
protector is not supplied as part of the standard package. It can be
ordered from GO Networks as an accessory.
Specific installation may require different Power/Ethernet connections. See
Cable Connections for more details.
MBW 1100 (WLP) Safety Information
RF Exposure
The MBW 1100 (WLP), an outdoor access point, is compliant with the
requirements set forth in CFR 47 section 1.1307, addressing RF Exposure
from radio frequency devices as defined in OET Bulletin 65. The outdoor
access point antennas should be installed to provide a separation distance
of at least 3 feet (1 meter) from humans.
MBW 1100 (WLP) Lightning Protector
A lightning protector is required when the MBW 1100 (WLP) unit is
installed in an outdoor location and the Ethernet cable connects to an
indoor network device.
The purpose of the lightning protection is to protect people and equipment
located indoors from lightning that might strike the MBW 1100 (WLP) or its
outdoor cables. Therefore, the lightning protector device should be
installed indoors, as close as possible to the point where the cables enter
the building.
The lightning protector can also be installed outdoors, as long as the
cables that go from the lightning protector to the indoors are well
protected from lightning between the box and the building entrance.
Verify that you have shared grounding. GO Networks offers a lightning
protector that can be ordered separately.