Grounding Cable
Connect a grounding wire to the grounding screw at the bottom of the
MBW 1100 (WLP) unit. A 10 AWG grounding cable is required to ground
the MBW 1100 (WLP) unit.
Figure 10: Grounding Connection
To ground the MBW 1100 (WLP) unit:
1. Crimp the solderless ring terminal [A] contained in the MBW 1100
(WLP) Connectors Kit to the grounding cable.
2. Attach the solderless ring terminal [A] to the bottom of the MBW
1100 (WLP) unit using the grounding screw.
3. Connect the other end of the grounding cable to a proper ground.
Note: Connect the 10 AWG grounding cable before connecting any other
cables. When removing the MBW 1100 (WLP), the grounding cable
should be the last cable removed.
Noter: Connecter la prise de terre 10 AWG avant de connecter tout autre
câble. Pendant la désinstallation du MBW 1100 (WLP), la prise de
terre doit être le dernier câble retiré.