User manual
GLP German Light Products GmbH
impression X4 L User Manual Rev. B from software version: v045 8
3.1.2 Mounting in hanging position (head down):
To operate the
IMPRESSION X4 L in a hanging position two (2) omega
brackets can be mounted directly to the bottom of the base using the
four (4) Camlock connectors.
Alternatively two (2) half-couplers (clamps or hooks) can be mounted directly to the
bottom side of the fixture using the two (2) M10x16 mm thread bolts.
Attention: Never use a longer bolt as this may damage the interior of the
fixture.