GLP® FR10 Bar Quick Start and Safety Manual – Revision A This manual covers fixture software version V. 20 © 2019 German Light Products GmbH. All rights reserved. The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of German Light Products GmbH in Germany, in the United States of America and in other countries. The information contained in this document is subject to change without notice.
Table of Contents 1. Safety ................................................................................................. 4 Key to symbols .............................................................................. 4 General safety information ......................................................... 4 Electrical safety ............................................................................ 5 Fire safety and protection from burns........................................ 6 Eye safety .............
www.glp.de 1. Safety Key to symbols The following symbols are used in this Guide: Warning! Safety hazard. Risk of severe injury or death. Warning! Hazardous voltage. Risk of lethal or severe electric shock. Warning! See user manual for important safety information. Warning! Fire hazard. Warning! Risk of eye injury. General safety information Read this manual carefully before installing, using or servicing the GLP impression FR 10 Bar lighting fixture.
German Light Products® precautions it contains before installing or using the fixture. GLP and affiliated companies will take no responsibility for damage or injury resulting from disregard for the information in the user documentation. • Check the GLP website at www.glp.de and make sure that you have the latest version of this manual. Check the fixture software version indicated on page 2 of this manual and then use the fixture’s control panel to check the version installed in the fixture.
www.glp.de • Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s Mains OUT (Thru) connector to another fixture’s Mains IN connector. • Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum 16 A-rated and temperature-rated to suit the application. In the USA and Canada the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be type H05VV-F or equivalent.
German Light Products® clean and unobstructed at all times in order to prevent a fire hazard and damage to the fixture. • The fixture’s optical components can focus the sun’s rays, creating a risk of fire and damage. Do not expose the front of the fixture to sunlight or any other intense light source, even from an angle. Eye safety • The FR 10 Bar is classified as a Risk Group 2 lighting fixture according to EN 62471. Possibly hazardous radiation emitted.
www.glp.de Installation safety and protection from personal injury • Installation must be performed by qualified personnel only and carried out in accordance with applicable regulations such as DIN VDE 0711-217. • The fixture is not portable when installed. • Ensure that the supporting structure and installation hardware used can hold at least ten times the weight of the load that they support.
German Light Products® 2. Avoiding damage to the fixture Important! Follow the directions in this section carefully, or the fixture may suffer damage that is not covered by the product warranty. General precautions Do not drop the fixture or expose it to mechanical stress. Protect the LCD display and control panel from shocks, or they may suffer damage that is not covered by the product warranty. Do not expose the fixture to heat (from other lighting fixtures for example).
www.glp.de Do not operate the fixture in ambient temperatures above 45° C / 113° F or below 5° C / 41° F. Allow free airflow around the fixture. Avoiding damage from dust and airborne particles • Carry out regular visual inspections of the fixture to make sure that there is no accumulation of dirt, especially on the front of the fixture and around air vents. • If cleaning is necessary, follow the instructions in ‘Service’ on page 20.
German Light Products® 3. FR 10 Bar overview A B D J C E F H G I K Figure 2.
www.glp.de 4. Features The impression FR 10 Bar from GLP can be used in dry locations in permanent and temporary installations. Fixtures can be placed on or fastened to a level surface, or they can be suspended from a suitable structure as directed in this manual. Power and data can be daisy-chained for ease of installation, and multiple fixtures can be lined up to give an unbroken line of pixels using the retractable alignment pins that are built into the fixture.
German Light Products® 5. Installation Warning! Read ‘Safety’ starting on page 4 for important safety information that you must understand before you install or operate the fixture. Install FR 10 Bar fixtures only as described in this chapter, or you may create an installation that is unsafe. It is the installer’s responsibility to provide a stable, secure supporting structure that is suitable for the environment and application and that meets all applicable codes and legal requirements.
www.glp.de Loop the cable around a secure anchoring point such as a truss chord or fixed structure so that it will catch the fixture if a rigging clamp fails. Take up as much slack as possible in the safety cable (by looping it more than once around the truss chord, for example). See Figure 4. Open one of the retractable safety cable attachment eyelets (arrowed) in the sides of the fixture and fasten the safety cable to it.
German Light Products® Installing on a rigging truss or similar structure You can suspend an FR 10 Bar fixture from a rigging truss or pipe using the brackets that are supplied with the fixture and rigging clamps that are available from GLP as optional accessories. If you are going to install the fixture hanging vertically downwards from a horizontal rigging truss or pipe, you can fasten it to the truss using G-clamps.
www.glp.de 6. AC mains power Warning! Read ‘Safety’ starting on page 4 for important safety information that you must understand before you install or operate the fixture. Check that all cables and connectors are suitable for the installation environment and application (see recommendations in ‘Avoiding damage to the fixture’ on page 9). Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum 16 A-rated and temperature-rated to suit the application.
German Light Products® Installing power connectors If you intend to draw power from convenience receptacles / consumer mains power sockets, it is possible to install a suitable cord cap / power plug on the supplied power cord / input cable. If you do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a connection to ground / earth and that it has an integral cable grip. Follow the cord cap / plug manufacturer’s assembly instructions.
www.glp.de 7. Connecting to DMX data Check that all cables and connectors are suitable for the installation environment and application (see recommendations in ‘Avoiding damage to the fixture’ on page 9). The FR 10 Bar supports USITT DMX 512A, Art-Net and sACN DMX control data signal protocols. It also supports RDM (Remote Device Management). Two types of data connection are available: • Two 5-pin XLR connectors for IN and THRU connections on a DMX data link using standard DMX protocol.
German Light Products® 8. Starting and stopping operation Warning! Before you apply power to the fixture or operate it after a blackout, make sure that nobody is looking directly into the front of the fixture and that there is sufficient clearance for the head to tilt safely.
www.glp.de 9. Service Warning! There are no user-serviceable parts inside the fixture. Any service operation that requires removal of a cover must be performed by a professional service technician with the tools, skills, and personal protective equipment to maintain high-powered lighting equipment safely and efficiently. Removing the front cover The FR 10 Bar is supplied with a clear front cover installed.
German Light Products® GLP Service and Support Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers: • GLP Germany: +49 (7248) 927 19-55 • GLP N. America: +1 818 767-8899 • GLP UK: +44 1392 690140 • GLP Asia: +852 (3151) 7730 • GLP Nordic: +46 737 57 11 40 Impression FR10 Bar Quick Start and Safety Manual Rev.
www.glp.de 10. Technical specifications Optics Total luminous output: 5860 lumens (wide), 4374 lumens (narrow) Light source: 10 x 60 W OSRAM Ostar RGBW LEDs Lifetime: 50 000 hrs. approx. to > 70% luminous output Zoom ratio: 1:7 Minimum zoom angle: 3.
German Light Products® Electrical AC mains power: 100-240 V nominal, 50/60 Hz Power supply unit: Auto-ranging electronic switch mode Maximum power consumption, all LEDs at 100% output: 800 W Idle power consumption, all LEDs at 0% output: 80 W Primary fuse: T 12 A, 250 V, 6x32 mm Maximum permitted number of fixtures daisy-chained to power 2 x FR 10 Bar total @ 100-120 V, 60 Hz 4 x FR 10 Bar total @ 200-240 V, 50 Hz Connections AC mains power IN and THRU: Neutrik powerCON TRUE1 Standard DMX data link IN and
www.glp.de 11. Dimensions FR 10 Bar All dimensions are in millimeters 1000 209 339 189 Folding brackets 69 130 130 196 970 138 24 60 138 370 impression FR10 Bar Quick Start and Safety Manual Rev.