Owner manual

0020096883_02 - 08/10 - Glow-worm
- 6 -
INTRODUCTION
2.4 Example of Installation – diagram 9 (9.3) : HYBRID COMPACT with 3 low heating temperature
zones (30-40°C) or 3 high heating temperature zones (< 80°C)
15 Climapro2 RF programmable wireless room thermostat "zone 1"
16 Heating circuit "zone 1" (*)
17 2 port valve "zone 1"
18 Overheatingsafety(ifunderoorheating)
19 Glycol PRV discharge
20 Heatpumpcircuitlter(notsupplied)
A Heat pump circuit return
B Heatpumpcircuitow
C Cold water supply
D Domestichotwaterow
E Boilercircuitow
F Boiler circuit return
G Heatingcircuitow
H Heating circuit return
I Heat pump circuit safety valve discharge
(*) UFHshown,butcanbeunderoororradiators
Key
1 Heat pump
2 Systempro control unit
3 "Compact" hydraulic module
4 Heat pump electrical supply + protection (This must have it's
own single isolation)
5 Wireless outdoor sensor
6 Domestic hot water cylinder
7 EBUS boiler
8 2 port valve "zone 3"
9 Climapro2 RF programmable wireless room thermostat "zone 3"
10 Heating circuit "zone 3" (*)
11 Climapro2 RF programmable wireless room thermostat "zone 2"
12 Heating circuit "zone 2" (*)
13 2 port valve "zone 2"
14 Domestic hot water cylinder 2 port valve
EBUS
B
A
G
H
E
F
I
230V
D
C
2
1
3
4 14
5
7
6
10
9
8
11
12
13
17
18
15
16
20
19
b
This diagram shows the case of an installation with
a three zone low temperature heating oor (= outlet
temperature < 40°C).
Zones must be same temperatures.
i
Refer to the chapters “Hydraulic connection” and
“Electrical Connection” to connect the system.
i
DHW components only necessary with sealed
system or open vented installations. Hot water
production can be via a combi boiler instead.