Owner manual
0020096883_02 - 08/10 - Glow-worm
- 5 -
INTRODUCTION
2.3 Example of Installation – Diagram 9 (9.2) : HYBRID COMPACT with 2 low heating temperature
zones (30-40°C) or 2 high heating temperature zones (< 80°C)
14 2 port valve "heating zone 1"
15 Overheatingsafety(ifunderoorheating)
16 Glycol PRV discharge
17 Heatpumpcircuitlter(notsupplied)
A Heat pump circuit return
B Heatpumpcircuitow
C Cold water supply
D Domestichotwaterow
E Boilercircuitow
F Boiler circuit return
G Heatingcircuitow
H Heating circuit return
I Heat pump circuit safety valve discharge
Key
1 Heat pump
2 Systempro control unit
3 "Compact" hydraulic module
4 Heat pump electrical supply + protection (This must have it's
own single isolation)
5 Wireless outdoor sensor
6 Domestic hot water cylinder
7 EBUS boiler
8 Climapro2 RF programmable wireless room thermostat "zone 2"
9 Heatingcircuit"zone2"(UFHshown,butcanbeunderooror
radiators)
10 2 port valve "heating zone 2"
11 Domestic hot water cylinder 2 port valve
12 Climapro2 RF programmable wireless room thermostat "zone 1"
13 Heatingcircuit"zone1"(UFHshown,butcanbeunderooror
radiators)
i
Refer to the chapters “Hydraulic connection” and
“Electrical Connection” to connect the system.
i
DHW components only necessary with sealed
system or open vented installations. Hot water
production can be via a combi boiler instead.
b
This diagram shows the case of an installation with a
dual zone low temperature heating oor
(= outlet temperature < 40°C).
Zones must be same temperatures.
EBUS
G
H
B
A
E
F
I
230V
D
C
2
1
3
4 11
5
7
6
8
9
10
14
15
12
13
17
16