INSTALLATION
Using the buttons ,
select Connection on the screen.
Press the button
to conrm.
Press the button on the outdoor
sensor to connect.
ON
1
Key
1 Outdoor sensor button
i
Once the sensor is detected, the message
«Connection completed» is displayed.
If unsuccessful, the message "Connection failure" is
displayed.
Press the button and repeat the operation.
Press the button
.
i
The External T°C Correction allows you to correct
the temperature measured by the outdoor sensor
(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).
Using the buttons ,
select External T ºC correction on
the screen.
Press the button
to conrm.
This setting is automatically modied in
the installer room thermostat menu.
Increase or decrease with the
buttons
to display the
desired correction.
Press the button
to conrm.
Press the button
twice.
12.6 Self check
e
Do not modify the cables when connected to the
mains.
The automatic test allows you to check:
- EBUS inputs,
- NTC inputs,
- the RF connection with the room thermostat,
- the outdoor sensor radio connection.
The other connections are not tested and should be
visually inspected during installation or conguration
modications.
Using the buttons ,
select Self check on the screen.
Press the button
to conrm.
Check that all installation’s
components are switched on.
Conrm the start of the test with the
button
.