6.5.3 System connection
• Refer to the table below for the wiring of the systempro.
- Diagram 9 (9.1) : HYBRID COMPACT with 1 low heating
temperature zone (< 40°C) or 1 high heating temperature
zone (< 80°C)
Key Description Cable min.
230V~ Control unit electrical supply 3 x 0.75 mm²
REL1 Pump of the hydraulic module 3 x 0.75 mm²
REL2 DHW cylinder 2 port valve (*) 3 x 0.75 mm²
REL5 Heating circuit 2 port valve 2 x 0.75 mm²
IN1 DHW cylinder thermostat (*) 2 x 0.75 mm²
NTC1
Heating ow thermistor of the hydraulic
module
2 x 0.34 mm²
NTC2 DHW cylinder thermistor (*) 2 x 0.75 mm²
EBUS EBUS connection of the heat pump 2 x 0.75 mm²
EBUS
EBUS connection of the boiler (respect the
polarity +/-)
2 x 0.75 mm²
(*) Not applicable for combi installations
- Diagram 9 (9.2) : HYBRID COMPACT with 2 low heating
temperature zone (< 40°C) or 2 high heating temperature
zone (< 80°C)
Key Description Cable min.
230V~ Control unit electrical supply 3 x 0.75 mm²
REL1 Pump of the hydraulic module 3 x 0.75 mm²
REL2 DHW cylinder 2 port valve (*) 3 x 0.75 mm²
REL4 Heating circuit 2 port valve "area 2" 2 x 0.75 mm²
REL5 Heating circuit 2 port valve "area 1" 2 x 0.75 mm²
IN1 DHW cylinder thermostat (*) 2 x 0.75 mm²
NTC1
Heating ow thermistor of the hydraulic
module
2 x 0.34 mm²
NTC2 DHW cylinder thermistor (*) 2 x 0.75 mm²
EBUS EBUS connection of the heat pump 2 x 0.75 mm²
EBUS
EBUS connection of the boiler (respect the
polarity +/-)
2 x 0.75 mm²
(*) Not applicable for combi installations
- Diagram 9 (9.3) : HYBRID COMPACT with 3 low heating
temperature zone (< 40°C) or 3 high heating temperature
zone (< 80°C)
Key Description Cable min.
230V~ Control unit electrical supply 3 x 0.75 mm²
REL1 Pump of the hydraulic module 3 x 0.75 mm²
REL2 DHW cylinder 2 port valve (*) 3 x 0.75 mm²
REL3 Heating circuit 2 port valve "area 3" 2 x 0.75 mm²
REL4 Heating circuit 2 port valve "area 2" 2 x 0.75 mm²
REL5 Heating circuit 2 port valve "area 1" 2 x 0.75 mm²
IN1 DHW cylinder thermostat (*) 2 x 0.75 mm²
NTC1
Heating ow thermistor of the hydraulic
module
2 x 0.34 mm²
NTC2 DHW cylinder thermistor (*) 2 x 0.75 mm²
EBUS EBUS connection of the heat pump 2 x 0.75 mm²
EBUS
EBUS connection of the boiler (respect the
polarity +/-)
2 x 0.75 mm²
(*) Not applicable for combi installations
6.5.4 Connection of the 2 port valve
13
LN
230V~
13
LN
REL1
13
LN
REL2
13
LN
REL3
12
LN
REL4
12
LN
REL5
12
LN
IN1
When the 2 port valve is connected to REL3:
• Connect the neutral wire (blue) of the valve to the “N” of the
REL3 connector.
• Connect the live wire (brown) of the valve to the “L” of the
REL3 connector.
• Connect the earth wire (yellow/green) of the valve to the
earth of the REL3 connector.
• Electrically insulate the red and grey wires of the valve as
they are not used.
When the 2 port valve is connected to REL4 or 5:
• Connect the neutral wire (blue) of the valve to the “N” and
the live wire (brown) of the valve to the “L” of the REL4 or 5
connector.
• Connect the earth wire (yellow/green) of the valve to the
earth of the REL3 connector.
• Electrically insulate the red and grey wires of the valve as
they are not used.