User guide
0020096881_02 - 08/10 - Glow-worm
- 8 -
INSTALLATION
7 Hydraulic connection
i
A label located inside the cover enables the
identication of the module’s hydraulic connections.
1
Key
1 Hydraulic connection label
B
A
C
D
E
F
G
Key
A Boilerowcircuitؾ"
B Boilerreturncircuitؾ"
C Heatingreturncircuitؾ"
D Heatingowcircuitؾ"
E Safety valve discharge
F HeatpumpreturncircuitØ1"
G HeatpumpowcircuitØ1"
• Take care to clean the pipes before assembly removing any
debris or burrs. Grease and oils may need to be removed
they are not possible to remove by cleansing and ushing.
Foreign bodies in the system may enter the appliance and
interrupt its operation.
• Do not use any solvent products, due to the risk of damaging
the circuit.
a
Do not perform any 'hot work' directly under
the appliance, this may cause damage to the
appliance base. Heat may also damage the
isolation valves.
Always pre-assemble pipes before tting them to
the appliance.
• Only use original seals supplied with the appliance.
• Check that there are no leaks.