- 18 -
INSTALLATION
12 Activating the control unit
a
Ensure that the heat pump and heating circuits
have been lled.
e
Ensure that all the electrical connections have
been made.
Switch ON the circuit breaker which is located on the
electrical panel and connected to the control unit.
1
Key
1 Switch On (I) / Off (O)
Turn on the control unit (1) with the switch (2) in position (I).
When connected for the rst time, the installation menu is
displayed.
Use the buttons to select
a language.
Press the button
to conrm.
Enter the installer access code 96
with the buttons .
Press the button
to conrm.
12.1 Conguringtheinstallation
Follow and conrm the steps
prompted by the initial installation
aid.
Press the button
to conrm.
Your system corresponds to diagram
number "10" in the control unit.
Choose diagram number "10" with
the buttons
.
Press the button
to conrm.
Multizone kit' refers to zone valves for
more than one heating zone.
If so, choose "YES".
Use the button
to conrm and
follow the control unit instructions.
If this is not the case and the
installation has only one zone, choose
"NO" with the buttons
.
Press the button
to conrm.
This screen is only displayed if you
answered “YES” to the previous
question.
Select number of heating zones
present on the system using the
buttons
.
- Z20 kit = 2 heating zones
- Z11 kit = not available
- Z30 kit = 3 heating zones
Press the button
to conrm.
Using the buttons ,
select DHW cylinder on the screen,
if the option is installed.
Press the button
to conrm.