User guide

0020154078_00 - 02/13 - Glow-worm
9
MOUNTING AND INSTALLATION
3.4 Type designation and serial number
Data plate location:
1
1
Key
1 Data plate
The type designation and the serial number are shown on the
data plate.
3.5 Data plate description
The data plate contains the following data:
Abreviation/
symbol
Description
Serial-no Commercial name and serial number
IP The electrical protection class
V/Hz
The pump + compressor + regulatory devices supply
voltage
I max The maximum current
R410A
The type of refrigerant uid, the amount necessary
for lling
PS
R The max. working pressure of the cooling circuit
PS
H min
PSH max
Minimum and maximum hydraulic pressure
COP (Ax/Wxx)
The coe cient of performance (COP) for an air
temperature of xx°C and heating ow temperature
of xx°C
(
Ax/Wxx)
The heating power for an air temperature of xx°C
and heating ow temperature of xx°C
EER
(
Axx/Wx)
The Energy E ciency Ratio (EER) for an air
temperature of xx°C and cooling ow temperature
of xx°C
(
Axx/Wx)
The refrigerating power f
or an air temperature of
xx°C and cooling ow temperature of xx°C
See chapter "CE label"
4 Mounting and installation
4.1 Preparing mounting and installation
4.1.1 Delivery, transport and installation on site
4.1.1.1 Transport
a
Warning!
Risk of injuries due to big carrying loads.
Too big carrying loads can cause injuries, e.g. on
the backbone.
Observe all relevant laws and other prescrip-
tions when carrying heavy products.
Refer to chapter 10 for the weight of the appli-
ance.
Plan two people at minimum to move
the appliance.
b
Caution!
Risk of equipment damage due to appliance
transport.
If the appliance is tilted more than 45° during
transport, the refrigerant circuit can be damaged
which may result in complete failure of the instal-
lation.
Do not tilt the appliance more than 45° during
transport.
1
1
Key
1 Transport strap