User guide
0020154078_00 - 02/13 - Glow-worm
22
TECHNICAL DATA
9.3 Refrigerant fl uid
b
Attention!
Risk of pollution!
This appliance contains R410-A refrigerant fluid
which must never be released to the atmosphere.
R410-A is a fluoride greenhouse gas covered by
the Kyoto protocol.
• Before discarding the appliance, correctly
recover the refrigerant fl uid into an appropriate
container to be recycled in compliance with the
regulations in force.
The recycling of the refrigerant fl uid must be performed by the
qualifi ed professional who installed the device.
The personnel approved for this recuperation must have an
appropriate certifi cation according to the regulations in force.
10 Technical data
i
This technical data is valid for a new appliance
with its own heat exchangers.
Description Unit Envirosorb3 8 Envirosorb3 11-1ph
Min. operating air temperature (heating and tank heating) °C -20 -20
Max. operating air temperature (heating) °C 35 35
Max. operating air temperature (domestic hot water) °C 46 46
Specifi cations, with radiators
(start : 45°C, return : 40°C, dry temperature (wet) 7 (6)°C)
Heating output kW 7,20 10,20
COP* A7(6) W45-40 3,5 3,35
(start : 55°C, return: 47°C, dry temperature (wet) : 7 (6)°C)
Heating output kW 6,60 9,40
COP* A7(6) W55-47 2,70 2.60
Specifi cations, with underfl oor heating
(start : 35°C, return : 30°C, dry temperature (wet) : 7 (6)°C)
Heating output kW 7,60 10,60
COP* A7(6) W35-30 4,50 4,30
(start : 35°C, return : 30°C, dry temperature (wet) 2 (1)°C)
Heating output kW 5,60 8,40
COP* A2(1) W35-30 3,40 3,10
Refrigerant circuit
Type of refrigerant R-410A
Quantity of refrigerant kg 1.950 3.530
Type of compressor Rotary
Type of oil specifi c Polyvinylether (PVE) oil.
Type of regulator Electronic
Maximum relative operating pressure (PS)
bar 41.5 41.5
Pa 41.5 x 10
5
41.5 x 10
5
Heat pump circuit
Min. fi lling pressure.
bar 1 1
Pa 1 x 10
5
1 x 10
5