Manual

11 0020013349-02
24cxi 30cxi 38cxi
Lift Weight 41kg(90lb) 42kg(92.5lb) 44kg(97lb)
Total Weight (installed) 44kg(97lb) 45kg(99lb) 47kg(103.5lb)
Gas connection 22mm copper
Heating and return 22mm copper
Domestic hot water 15mm copper
Safety valve Preset 3bar (43.5lbf/in
2
)
Safety valve discharge 15mm copper
Expansion vessel capacity 8 litres (1.76 gallons)
Charge pressure 0.5bar (7.3lbf/in
2
)
Heating system 0.7bar (10.1lbf/in
2
)
minimum pressure
Max. Domestic hot water flow rate
at 35
O
C rise 24 cxi 9.8L/min.
30 cxi 12.3L/min.
38 cxi 15.5L/min.
Min. Domestic hot water flow rate 24/30/38cxi 1L/min.
Maximum flow temperature 63
0
C
Maximum heating system 130 litres
water content using (28.6 gallons)
pressurised at 1bar. fitted expansion vessel,
at 75
0
C average system
temperature
Electrical supply 230V~50Hz
Electrical rating 180W fused 3A
IP classification X4D
Internal Fuse rating
On PCB 630mAT
TABLE 1
D.H.W Max. working pressure 10bar (145lbf/in
2
)
Minimum working pressure for
max. domestic flow rate 0.2bar (2.9lbf/in
2
)
1 Technical Information
Diagram 1.2
For larger systems use an additional
expansion vessel.
Ball valves are fitted in water and gas connections.
12923