Drawing Title:GT-43007-3612, ITE Power Supply/Class 2 Power Supply, Efficiency Level: V, Case Color/Style:
GlobTek Black, Wall Plug-in, Regulated Switchmode AC-DC, Input Rating: 100-240V~, 50-60 Hz,
Interchangeable Blades http://en.globtek.com/interchangeable-blades.php, Output Rating: 36W, 12V@3A,
Output Configuration: 1830 mm, 18/1C + Shield Cond, UL 1185, Female Barrel 5.5 * 2.5 * 11mm No internal
Spring Clip nor Locking Notch or Equal, Ferrite: Core Size: 14.2*28.5*8.2, GlobTek Black, GT Cord # C0478,
Pin Out: Center Positive (+V), Blades/Input Cord: Q-Series Europe, Approvals: CB, cETLus, cETLus UL1310,
China RoHS, FCC, GOST-R, IP52, Level V, LPS, PSE, RoHS 2, S-Mark, SELV, Ukraine, UL, UL/cUL, VCCI
Model No.GT-43007-3612
Part No.WR9QE3000LCPNEU(RVB) RevA
PROPRIETARY INFORMATION
PROPRIETARY OF GLOBTEK, INC. ANY REPRODUCTION, DISCLOSURE OR USE OF THIS DRAWING, IN WHOLE OR IN PART, IS HEREBY PROHIBITED EXCEPT AS SPECIFIED IN
WRITING BY GLOBTEK, INC.
rmünt /07/15/2014 11:23:18 AM
Page 2 of 11
POWER SUPPLY INFORMATION
TYPE: Wall Plug-in
TECHNOLOGY: Regulated Switchmode AC-DC
CASE COLOR: GlobTek Black
NAMEPLATE RATED
INPUT:
100-240V~, 50-60 Hz, 1.0A
INPUT CONFIG: Interchangeable Blades
WATTS: 36.0
VOLTS OUT: 12
CURRENT OUT (Amps): 3
BLADE/CORD INCLUDED: Q-EU:Q-Series Europe
BLADE/CORD INSTALLED: Q-EU:Q-Series Europe
EFFICIENCY LEVEL: V
OUTPUT
CONFIGURATION
1830 mm, 18/1C + Shield Cond, UL 1185, Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or
Equal, Ferrite: Core Size: 14.2*28.5*8.2, GlobTek Black, GT Cord # C0478
CONNECTOR PIN OUT: Center Positive (+V)
LABEL SPECS: Standard GT,L-1186
PACK SPEC: Standard WPI Q-EU installed, Individually Box
NOTES / DEVIATIONS:
DIMENSIONS ARE IN MM UNLESS SPECIFIED OTHERWISE.
ELECTRICAL SPECIFICATIONS
A) ELECTRICAL SPECIFICATIONS:
01.Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac
02.Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60 Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 1% typical measured the output connector
05. Output Ripple (Vp-p): +/-1% or 150 mV whichever is greater at nominal output voltage. Measured at 20 MHz bandwidth with 0.1 uf
ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector.
06 Turn-ON/OFF Overshoot: 5% maximum, 500uS max recovery time for 25% step load.
07. Turn-ON Delay: 3000 mS maximum.
08. Hold-Up Time: 10 mS Minimum at nominal input and full load.
09. Inrush Current: 30A maximum at cold start, 120Vac, 60A maximum cold start 230 Vac
10. Switching Frequency: 65 KHz typical
B) PROTECTION
01. Over-Voltage: Protected, unit will auto recover upon removal of fault
02. Short Circuit: Protected, unit will auto recover upon removal of fault
03. Input Protection: Input line fusing
C) SAFETY
01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary
02. Touch Current: <0.25mA @ 240Vac input voltage
03. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006
D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature
03. Humidity: 0% to 90% relative humidity
04. Storage Temperature: -40°C to 80°C
05. Cooling: Convection