Datasheet

GlobTek, Inc.
www.globtek.com
186 Veterans Drive,
Northvale, NJ 07647
Tel. (201) 784-1000
Fax (201) 784-0111
Drawing Title:GTM91099-6015-3.0-T2, Medical/ITE Power Supply, Efficiency Level: V, Case Color/Style:
GlobTek Black, Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC, Input Rating: 100-240V~,
50-60 Hz, Interchangeable Blades, Output Rating: 60W, 12V@5.0A, Output Configuration: 1200 mm, 16/1C +
Shield Cond, UL 1185, Female Barrel 5.5 * 2.5 * 11mm with no internal Spring Clip and Locking Notch or Equal,
Ferrite: None, GlobTek Black, GT Cord # C0408, Pin Out: Center Positive (+V), Blades/Input Cord: (Order
Separately), Approvals: CB, CCC, CE, China RoHS, cRUus, cUL, cUR, Double Insulation, EC, GOST-R, IP40,
IP52 Option, Level V, LPS, NEMKO, PSE, RCM, RoHS 2, Ukraine, VCCI, WEEE
Model No.GTM91099-6015-3.0-T2
Part No.RR9KE5000LCP-C-IM(RV RevF
PROPRIETARY INFORMATION
PROPRIETARY OF GLOBTEK, INC. ANY REPRODUCTION, DISCLOSURE OR USE OF THIS DRAWING, IN WHOLE OR IN PART, IS HEREBY PROHIBITED EXCEPT AS SPECIFIED IN
WRITING BY GLOBTEK, INC.
QA /06/09/2014 2:43:09 PM
Page 2 of 11
POWER SUPPLY INFORMATION
TYPE: Wall Plug-in+Desktop Combination
TECHNOLOGY: Regulated Switchmode AC-DC
CASE COLOR: GlobTek Black
NAMEPLATE RATED
INPUT:
100-240V~, 50-60 Hz, 1.5 A
INPUT CONFIG: Interchangeable Blades
WATTS: 60.0
VOLTS OUT: 12
CURRENT OUT (Amps): 5.0
BLADE/CORD INCLUDED: None:(Order Separately)
BLADE/CORD INSTALLED: None:(Order Separately)
EFFICIENCY LEVEL: V
OUTPUT
CONFIGURATION
1200 mm, 16/1C + Shield Cond, UL 1185, Female Barrel 5.5 * 2.5 * 11mm with no internal Spring Clip and Locking
Notch or Equal, Ferrite: None, GlobTek Black, GT Cord # C0408
CONNECTOR PIN OUT: Center Positive (+V)
LABEL SPECS: Standard GT,L-1186
PACK SPEC: Standard WPI, Individually Box
NOTES / DEVIATIONS:
DIMENSIONS ARE IN MM UNLESS SPECIFIED OTHERWISE.
ELECTRICAL SPECIFICATIONS
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% nominal output voltage measured at the output connector at nominal line
04. Line Voltage Regulation: +/- 2% max at full load
05. Output Ripple (Vp-p): +/-1% or 150mV whichever is greather at nominal output voltage. Measured at 20 MHz bandwidth with 0.1 uf
ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector.
06. Turn-ON/OFF Overshoot: 5% max, 500uS max recovery time for 25% to 50% step load
07. Turn-ON Delay: 2 Seconds, maximum @ full load, nominal line
08. Hold-Up Time: 8 mS at nominal input and full load
09. Inrush Current: 40A max at cold start 120 VAC, 60A max cold start 230VAC
10. Switching Frequency: 100 KHz typical
B) PROTECTION
1. Over-Voltage: Protected, Hiccup with auto recovery
2. Short Circuit: Protected, Hiccup with auto recovery
3. Over-load: Protected, Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing
5. Means of Patient Protection: (2 x MOPP)
C) SAFETY
01. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
02. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
03. Means of Protection: 2 x MOPP
04. Primary to Secondary Bridging Capacitor: (2) * Y1 type capacitors in series
D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C