Mixer User Manual
Page 12
Your new Globe mixer will provide years of uninterrupted service, but only if you do the following.
Installation
•  Do not use an extension cord to connect electrical power.
•  Make sure all 3 Phase units (see data plate) run in the direction of the arrow on front of the machine.
Operation
•  Turn off the mixer prior to changing speeds.
•  Follow the capacity chart on page 13, especially for mixing dough.
• Use only fi rst (1) speed for mixing dough. 2nd speed should never be used on 50% AR or lower with the
  exception of the SP60P. The SP60P requires a 50% reduction in batch size to mix in speed 2 with 50% AR 
 doughs.
•  If the unit shuts off during mixing (overload protection trips), reduce the batch size.
Maintenance
• Add only 2 pumps of grease to the planetary grease fi tting once a year.
Important Points
Recommended Maintenance
PART REQUIRED ACTION   FREQUENCY 
Planetary Ring  Reapply grease (e.g. black axle grease).    Once a year.
  Inject grease (2 pumps only) into zerk fi tting 
  on the side of planetary. DO NOT over fi ll! 
Bowl Slide Rods  Apply Globe oil (mineral oil) on the bowl slide rods.  If the bowl becomes diffi cult to 
  Raise and lower the bowl to distribute the oil onto    raise or lower.
 the rods.
Gear Oil Meter  Contact a Globe authorized servicer to change the    Once a year. When the gear oil
(SP62P and  gear oil.    meter shows the oil being below 
SP80PL only)      half of the circle.