Conversion Kit Instructions for the Globe Gas Countertop Charbroiler
Rev. D O:\Service\Public\service bulletins\999241 Gas Conversion Charbroiler          
Charbroiler
Conversion Kit Instructions
Do not attempt gas conversion by yourself. Gas conversion of your unit is to be 
made by a certifi ed/licensed technician. Locate an authorized Globe servicer at 
www.globefoodequip.com or call 800-347-5423. 
CONVERSION
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion should be 
done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on 
natural gas. Parts necessary for L.P. (liquid propane) are provided with the unit. Turn off the main gas supply 
before doing any maintenance. (Use only factory supplied regulator!)
1. Remove the knobs and front panel.
2. Unscrew bolts and pilot valve, then 
 remove the manifold.
3. Replace the orifi ce fi ttings into the valve.
 Note: Unit Number on side of orifi ce
 fi ttings.
4. Replace the front panel and knobs
NAT
L.P.
5. Before installing the included convertible
 regulator, unscrew the octagon cap. You can read
 (NAT) on the plastic insert attached to the head of 
 the cap; fl ip it over and snap back in place.
Convertible 
regulator with 
octagon cap. 
Unscrew from 
regulator.
Pictured is 
the plastic 
insert. Pull 
off insert 
from octagon 
cap and 
reverse the 
plastic insert 
position so 
that the L.P. 
position is 
attached to 
the octagon 
cap head.
L.P. Position 
of insert. 
Regulator 
is now 
converted to 
L.P.
6. Continue with installation.
L.P.
L.P. Position
Pg 2 of 4