User's Manual

Improper wiring of any electrical device can cause fire, serious injury or death. Always consult a qualified licensed electrician who will ensure the switch is installed in accordance with local electrical
codes and regulations. Before starting installation, ensure the power is disconnected at the circuit breaker and test existing switch with a voltage tester.
Caution
• Make sure that the power at the circuit breaker is off before wiring.
• Neutral wire is required. Confirm the wall box contains a neutral wire (typically white).
• The wire colours indicated in this manual are the common colors and may differ in some homes. Please contact an electrician if you have different wire colours.
• Ensure the wire conductors are securely fastened to each wire.
• DO NOT USE WITH STANDARD DIMMER.
Step 1
Turn power OFF from the electrical panel prior to installation.
Step 2
Determine the location for installation and cut a hole of the
appropriate size in the ceiling. Refer to the hole diameter table for
appropriate sizes or use the supplied template on the “Hole Size” page.
Step 3
- Open the junction box cover and remove the appropriate knockout(s)
on the side panel.
- Insert the electrical supply cable through the knockout. If you do not
have electrical wiring experience, Globe recommends consulting a
qualified licensed electrician who will ensure the fixture is installed in
accordance with local installation codes.
- Using quick-connect push-in terminals, connect the green ground
wire to the green wire terminal; the black wire to the black wire
terminal; the white wire to the white wire terminal.Use the cable clamp
to secure wire in knockout hole.

Compare all parts with the “Hardware Included” section. If any part appears missing or damaged, do not install this product and contact the Customer
Service team at 1-888-543-1388 or e-mail to info@globe-electric.com.
Tools Required

NOTE: Hardware is not shown to actual size.
INSTALLATION
cutting hole diameter
6.3 inch slim
6 1/4 ± 1/8 (160 ± 3mm)

Item
light panel + receiver + cable
junction box + cable
foam gasket
12 watt
CRI 90
IC-rated
Minimum starting temperature: -18˚C (0˚F)
1
1
1


Ladder
Safety goggles Wire strippers Pencil
Gloves
Drywall saw Cable clamp