Instructions / Assembly

5
TER MO
WATER ENHANCEMENT
If replacing a tank
With all power turned o to the pump system, drain the old
tank, close all water flow to the tank and disconnect it from
the system. Check all fittings, valves, switches and gauges for
proper working condition and replace as appropriate.
Connecting tank to system
WARNING: Disconnect or shut o all electric power to the
water supply/pump system. Shut o the water supply to
the system and remove all water pressure from the system.
Failure to follow these instructions may result in serious
injury, death and/or property damage and will void product
warranty.
WARNING: A suitable pressure relief valve, set at a
maximum of 125 psi, must be installed in the system near
the pressure tank (see Fig.1.1) The pressure tank should
be installed in the incoming water supply line from the
pump system and before any point of user (POU) fixtures.
(see Fig. 1.1)
Pressure
switch
Fig. 1.1
EASY AS 1-2-3 INSTALLATION
1. Remove and discard the protective cap from the pressure tank’s
stainless steel water connection. Connect the tank cross / tee
fitting (3- or 5- way connector for inline or horizontal pressure
tanks) into the pressure tank with adequate pipe sealant
(Teflon™ tape or pipe dope) on the male threads. Be cautious
to not over-tighten, cross, or strip threads when connecting
fittings.
2. Once the fitting is securely tightened, be sure that the
threaded holes for your pressure switch and pressure gauge
on the tank connection fitting are in the upward position. (See
vertical tank examples Figures 1.1, 1.2, and 1.3, horizontal tank
example Figure 1.4 and inline tank example Figure 1.5).
3. With adequate pipe sealant, connect all of the fittings, valves,
pressure switch, pressure gauge and water system pipe /
connection unions to the connection fitting.
WARNING: All piping and electrical components should be in
accordance with prevailing local codes and standards.
STARTING SYSTEM
Before turning on the water supply to the system, open a water
faucet to allow air from the system piping to be purged. Turn
on the power to the water supply and the pump should turn
on, filling the system piping. When the water is flowing freely
from the faucet without air, close the faucet. The pump will
continue to run filling the pressure tank.
WARNING: Inspect the installation for water leaks paying
close attention to the connection between the pressure tank
and the system piping.
TYPICAL INSTALLATIONS
Fig. 1.2 With submersible pump