Manual

SmartOne Manual Rev 1.4 DOC# 9100-0268-01 p.65
7
Input 1 count 8
The total number of openings or
closings of input 1 as selected
by the user. (OxFF means that
Input 1 Accumulate has been
turned off)
8
Input 2 count 8
The total number of openings or
closings of input 2 as selected
by the user. (OxFF means that
Input 1 Accumulate has been
turned off)
Table 11 – Accumulate/Count Message
Messaging Priority
Prioritization of Periodic Standard Message Report Rates
The SMARTONE supports several rates at which it will send a periodic
standard message. Periodic, scheduled standard message rates are
mutually exclusive. This is the priority of the different rates at
which the SMARTONE will send a standard message. Highest is listed
first:
Rate specified by Undesired Input State.
Rate specified for when the SMARTONE is inside its Change of Location
Area.
Rate specified for when device is In Motion. (Note, when inside the
Change of Location Area, this rate affects sampling, but not reporting,
as indicated by a higher priority for inside Change of Location Area.)
Rate specified for when the device is At Rest.