Manual

=
Specifications
Model
1302-B
DUAL 0 TO 32V SECTION
Output Voltage 1 & 2
0-32 DC continuously variable by voltage control
Load Current 1 & 2
0-2 Amp max., continuously variable by current control
CONSTANT VOLTAGE MODE OPERATION
Line Regulation
±0.01% +2mV for ±10% line change
Load Regulation
±0.01% +2mV for load change from zero to full load
Ripple & Noise
1mV rms max
CONSTANT CURRENT MODE OPERATION
Line Regulation
±0.1%+250µA for ±10% line change
Load Regulation
±0.1%+250µA for change in output voltage form 0 to maximum
Ripple & Noise
0.8 mA rms max
METERING
Two separate 3 digit DPMs are provided for O/P 1 and O/P 2
Meter Selection
Switch selection for voltage or current monitoring
Meter Accuracy
±0.5% of rdg. +2 counts
Overload Protection
Automatic overload and short circuit protection
5V SECTION
Output Voltage
4.5 VDC to 5.5VDC
Output Current
5A max with foldback current limit
Ripple & Noise
2mV rms max
GENERAL
Operating Temp
0 deg to 40 deg C
Input Voltage
110-120VAC @ 60Hz or
220-240VAC @ 50Hz
Dimensions
9” (W) x 11.5” (D) x 5.5” (H)
Weight
20 lbs, 6 ox net. approximately
Technical data subject to change without notice.