User's ManualUser's Manual
17" Electric Auto
Floor Scrubber
User's Manual
Problem Cause Solution
No power
Unit not plugged in.
Open circuit breaker.
Plug in the unit.
Turn on circuit breaker.
Little or no
solution flow
Water flow tap closed.
Clogged solution tank filter.
Empty solution tank.
Open water flow tap.
Clean solution tank filter.
Fill the solution tank.
Poor water pickup
Squeegee clogged.
Squeegee blades worn.
Squeegee not mounted correctly.
Clean debris from squeegee with damp towel.
Install new squeegee blades.
Confirm that the squeegee assembly is securely fastened
to the machine and not loose fitting.
Vacuum hoses have a hole or are loose.
Vacuum hose may be clogged.
Check hose connections and make sure they are firm.
Replace hose if damaged.
Check hose for debris and remove any clogs.
Drain hose stopper is loose.
Recovery tank is open.
Tighten drain plug.
Confirm the clear recovery tank lid is securely in place.
Recovery tank is full. Drain recovery tank.
Float shut off is clogged.
Remove float shut off from inside recovery tank and
remove any debris.
Vacuum motor is loose.
Tighten vac motor mounting screws. DO NOT over tighten
or damage will occur
Troubleshooting
Monthly Maintenance
• Flush out solution tank with clean water.
• Remove the clear cap and the solution tank filter. Clean
the filter with clean water
• Motors should be tested every 250 hours. Turn on/
off both Pad/Brush and Vacuum motor to ensure the
motors are working properly
Daily Maintenance
• Wipe the whole machine with clean/damp cloth
• Empty the solution tank by opening solution drain plug
location on the bottom
Squeegee Rubber Blade Replacement
• Remove the squeegee assembly from the unit (refer to
squeegee assembly installation).
• Unlock the spring lock and slide out the blades.
• Replace with new blade and reassemble.
MACHINE STORAGE
MAINTENANCE
• Drain and rinse out recovery tank with clean water
• Remove the Pad Driver/Brush and Squeegee assembly
and Clean with clean water
• Store the machine indoor in a dry location
• Always store the machine with the squeegee and pad/
driver raised off the floor
• Always drain the solution and recovery tank fully before
storing, especially when storing in a cold location