Air Source Installation
1. Clean all connecting pipes and joints to prevent dirt from entering the gas tubes
when installing the air regulator.
2. Ensure the air ow matches the direction indicated by the arrow on the body.
3. Drain the water from the lter by pushing the drain button upward.
4. The pressure is preset to 0.3-0.4 MPa. However, you can adjust the pressure by using
the pressure knob if needed. Pull the knob up to unlock the knob. Turn the knob
gradually (clockwise to increase outlet pressure and counterclockwise to decrease).
DO NOT change the pressure drastically too quickly. Press the knob down to x the
setting.
5. Fill the oil feeder with mechanical oil (ISO VG32 or equivalent) to no more than 80%
of capacity.
Note: Air inlet connects to 8mm OD x 5mm ID air pressure hose.