User Manual
7
CONTROL PANEL OPERATION(CONTINUED)
Accessory
THIS UNIT IS CONTROLLE D BY WA L L MOUNTED THERMOSTAT
NOTE:When the unit displays LC (Pads on the
control panel is not available.The unit can be setted
by using wire cotroller only.) You can install the
Accessory on the control panel.
NOTE: For some models, there is corresponding
operation happened after 3 seconds when pressing
any button.
NOTE: When there are wide differences between
USERS MANUAL and Remote controller Illustration
on function description, the description on USERS
MANUAL shall prevail.
NOTE:This air conditioner is designed to be
operated under the following condition:
Note: Performance may be reduced outside of
these operating temperatures.
Cooling
operation
Outdoor temp:
O O O O
18-43 C/64-109 F (18-52 C/64-125 F
for special tropical models)
Indoor temp:
Heating
operation
Outdoor temp:
Indoor temp:
O
O
17-32 C/62-90 F
-5-24
O
O
C/23-76 F
O
O
0-27 C/32-80 F
DIP SWITCHES CONFIGURATIONS
REMOVING THE FRONT PANEL
- Dip switches controls are located behind front panel,
through an opening below the control panel.To
access,remove front panel.See Fig.2.
-
Dip switches are accessible without opening the
control box.See Fig.3.
- Unit must be powered OFF to effectively change
their status.
2
1
Fig.2
- Pull out at the bottom to release it from the tabs .
- Then lift up .
1
2
DIP SWITCHES CONFIGURATIONS
- See Table 1 and Fig.4 for Dip Switches configurations
and functions of each dip switch position.
UP(ON)
DOWN(OFF)
Fig.4
Dip Switches
Fig.3
1 2 3 4 1 2 3 4
S1
S2
S3
S4
S5
S6
S7
S8
S9
X
A0-
A3
Wall thermostat type
Heating type
Temperature display type
Control type
Setpoint limit 1
Setpoint limit 2
Fan CON/CYC for cooling
Fan CON/CYC for heating
1 2 1 2 3 4
Low temp. Protection
S11
Load delay for 3 seconds